3F Six R Wide
Code
Item
Absorbed
power (W)
Output
flux (lm)
CCT
(K)
CRI
Dimensions
L x A x H
IP
ON/OFF electronic wiring 230V‑50/60Hz
22230
3F Six R 85/840 WIDE 596x596
89
13622
4000
>80
596x596x70
40
22231
3F Six R 70/840 WIDE 596x596
72
11050
4000
>80
596x596x70
40
22232
3F Six R 60/840 WIDE 596x596
62
9530
4000
>80
596x596x70
40
DALI electronic wiring 230V‑50/60Hz
22233
3F Six R 85/840 DALI WIDE 596x596
89
13622
4000
>80
596x596x70
40
22234
3F Six R 70/840 DALI WIDE 596x596
72
11050
4000
>80
596x596x70
40
22235
3F Six R 60/840 DALI WIDE 596x596
62
9530
4000
>80
596x596x70
40
3F Six R Medium
Code
Item
Absorbed
power (W)
Output
flux (lm)
CCT
(K)
CRI
Dimensions
L x A x H
IP
ON/OFF electronic wiring 230V‑50/60Hz
22237
3F Six R 85/840 MEDIUM 596x596
89
13157
4000
>80
596x596x70
40
22238
3F Six R 70/840 MEDIUM 596x596
72
10673
4000
>80
596x596x70
40
22239
3F Six R 60/840 MEDIUM 596x596
62
9205
4000
>80
596x596x70
40
DALI electronic wiring 230V‑50/60Hz
22240
3F Six R 85/840 DALI MEDIUM 596x596
89
13157
4000
>80
596x596x70
40
22241
3F Six R 70/840 DALI MEDIUM 596x596
72
10673
4000
>80
596x596x70
40
22242
3F Six R 60/840 DALI MEDIUM 596x596
62
9205
4000
>80
596x596x70
40
3F Six R UGR
Controlled symmetric distribution.
Average luminance <3000 cd/m² for radial angles >65°.
Code
Item
Absorbed
power (W)
Output
flux (lm)
CCT
(K)
CRI
Dimensions
L x A x H
IP
ON/OFF electronic wiring 230V‑50/60Hz
22244
3F Six R 40/840 UGR 596x596
43
6621
4000
>80
596x596x70
40
DALI electronic wiring 230V‑50/60Hz
22245
3F Six R 40/840 DALI UGR 596x596
43
6621
4000
>80
596x596x70
40
Construction characteristics
Illuminotechnical characteristicsDirect symmetric distribution.
Lifetime (L93/B10): 30000 h. (tq+25°C)
Lifetime (L90/B10): 50000 h. (tq+25°C)
Lifetime (L85/B10): 80000 h. (tq+25°C)
Lifetime (L80/B10): 100000 h. (tq+25°C)
Photobiological safety in compliance with IEC/TR 62778: RG0 risk exempt, (IEC 62471).
Mechanical characteristicsHousing in galvannealed steel, painted in white epoxy‑polyester.
PMMA lenses with external flat surface.
Electrical characteristicsIn compliance with EN 60598‑1.
Compliance with the EN 60598‑2‑22 standard for power supply from a centralised CPSS emergency system must be verified in the technical data sheets of each individual device on our website.
Power cable type H05Z1Z1‑F 3‑5x1.5 mm² that protrudes by 1 m with sheared ends.
Source characteristics
- Linear LED modules.
- Colour initial tolerance (MacAdam): SDCM 3.
On request
- different light distributions
- different power levels, colour rendering indices and colour temperatures
- wiring: CLO
- different dimensions
- emergency versions
Applications
Environments: commercial, exhibition areas, transit areas, lobbies or waiting rooms, shops.
UGR versionEnvironments that need luminance control.
Luminaires suitable, from a hygienic point of view, for use in production plants in the food industry (HACCP / IFS / BRC‑Standard).
Installation
Lay‑in installation.
Light Management
The DALI products of this family can be controlled manually with the technology 3F Easy Dim or even automatically and manually using the 3F Smart Dimming technology (refer to "Light Management").
Adapter frame in white‑painted steel, for installing luminaries with dimensions of 596x596 mm for pull‑up installations on plasterboard false ceilings.
Anti‑fall safety cable with pair of brackets for fixing the housing to the building structure.
Length 2.5 m.
White aluminium frame.
Height 80 mm.
Code
Item
3FLPLAFO604 - 60x60 ceiling frame kit