3F Linux DR
Diffused symmetric distribution.
Rectangular opal polycarbonate diffuser.
Structure height (3F Linux S + 3F Linux DR) equal to 81 mm.
Code
Item
Absorbed
power (W)
Output
flux (lm)
CCT
(K)
CRI
Dimensions
L x A x H
IP
ON/OFF electronic wiring 230V‑50/60Hz
A20512
3F Linux DR 2x22 LED L1778
49
6253
4000
>80
1778x62x47
40
A20511
3F Linux DR 2x30 LED L1778
66
7856
4000
>80
1778x62x47
40
DALI electronic wiring 230V‑50/60Hz
A20526
3F Linux DR 2x22 LED DALI L1778
49
6253
4000
>80
1778x62x47
40
A20525
3F Linux DR 2x30 LED DALI L1778
66
7856
4000
>80
1778x62x47
40
3F Linux DR UGR
Code A20596
L<3000 cd/m² 65°
Controlled symmetric distribution.
1x30 ‑ Average luminance <1500 cd/m² for radial angles >65°.
2x22 ‑ Average luminance <3000 cd/m² for radial angles >65°.
Rectangular transparent polycarbonate diffuser.
Semi‑specular aluminium internal louvre with prismatic methacrylate filter above the louvre blades for complete shielding of the louvre compartment.
Structure height (3F Linux S + 3F Linux DR) equal to 81 mm.
Code
Item
Absorbed
power (W)
Output
flux (lm)
CCT
(K)
CRI
Dimensions
L x A x H
IP
ON/OFF electronic wiring 230V‑50/60Hz
A20595
3F Linux DR 1x30 LED UGR L1778
34
3487
4000
>80
1778x62x47
40
A20596
3F Linux DR 2x22 LED UGR L1778
49
5361
4000
>80
1778x62x47
40
DALI electronic wiring 230V‑50/60Hz
A20599
3F Linux DR 1x30 LED DALI UGR L1778
34
3487
4000
>80
1778x62x47
40
A20600
3F Linux DR 2x22 LED DALI UGR L1778
49
5361
4000
>80
1778x62x47
40
3F Linux DR AS
Asymmetric distribution.
Rectangular opal polycarbonate diffuser.
Internal flow recuperator in white steel.
Structure height (3F Linux S + 3F Linux DR) equal to 81 mm.
Code
Item
Absorbed
power (W)
Output
flux (lm)
CCT
(K)
CRI
Dimensions
L x A x H
IP
ON/OFF electronic wiring 230V‑50/60Hz
A20674
3F Linux DR 2x30 LED AS L1778
66
6403
4000
>80
1778x62x47
40
DALI electronic wiring 230V‑50/60Hz
A20679
3F Linux DR 2x30 LED DALI AS L1778
66
6403
4000
>80
1778x62x47
40
Construction characteristics
Illuminotechnical characteristicsDirect distribution.
Lifetime (L93/B10): 30000 h. (tq+25°C)
Lifetime (L90/B10): 50000 h. (tq+25°C)
Lifetime (L85/B10): 80000 h. (tq+25°C)
Lifetime (L80/B10): 100000 h. (tq+25°C)
Photobiological safety in compliance with IEC/TR 62778: RG0 risk exempt, (IEC 62471).
Mechanical characteristicsLight unit in hot‑galvanised steel, painted in white polyester base with fixing springs and retractable safety hooks in stainless steel.
Rectangular screen in self‑extinguishing polycarbonate, UV stabilised, with smooth outer surface.
Electrical characteristicsIn compliance with EN 60598‑1.
Compliance with the EN 60598‑2‑22 standard for power supply from a centralised CPSS emergency system must be verified in the technical data sheets of each individual device on our website.
Connection to the structure with mobile plug with phase selection (H05Z‑U Halogen Free cable section 0,5 mm² HT90).
Source characteristics
- Linear LED modules.
- Colour initial tolerance (MacAdam): SDCM 3.
On request
- different powers
- LED sources with different colour temperatures
- housing in different RAL colours
- wiring: CLO
- emergency versions
Applications
Environments: commercial, exhibition areas, transit areas, lobbies or waiting rooms, shops, schools.
Installation
This lighting unit can be installed only on profile 3F Linux S | IP40.
Light Management
The DALI products of this family can be controlled manually with the technology 3F Easy Dim or even automatically and manually using the 3F Smart Dimming technology (refer to "Light Management").
Wall‑mounting bracket, in white painted steel.
Additional contact for light unit plug.
Code
Item
A20476
Contact pin for 3F Linux plug (50 pcs.)
The pack contains 50 pieces. Accessory not compatible with 3F Linux S‑NL (cod.: A20011, A20012).