3F Linda LED Transparent
Transparent polycarbonate housing.
Snug fit safety snap-lock clips in stainless steel.
Code
Item
Absorbed
power (W)
Output
flux (lm)
CCT
(K)
CRI
Dimensions
L x A x H
IP
Electronic wiring 230V-50/60Hz
58806
3F Linda LED Trasparente 1x12W L660
15
1928
4000
>80
660x100x100
65
58808
3F Linda LED Trasparente 1x24W L1270
28
3935
4000
>80
1270x100x100
65
58810
3F Linda LED Trasparente 1x30W L1570
35
4925
4000
>80
1570x100x100
65
58809
3F Linda LED Trasparente 2x24W L1270
56
7693
4000
>80
1270x160x100
65
58811
3F Linda LED Trasparente 2x30W L1570
70
9628
4000
>80
1570x160x100
65
Construction characteristics
Illuminotechnical characteristicsControlled symmetric distribution.
Lifetime (L92/B10): 30000 h. (tq+25°C)
Lifetime (L85/B10): 50000 h. (tq+25°C)
Lifetime (L80/B10): 80000 h. (tq+25°C)
Lifetime (L75/B10): 100000 h. (tq+25°C)
Photobiological safety RG0, risk exempt, in compliance with IEC 62471, IEC/TR 62778.
Mechanical characteristicsHousing in transparent self-extinguishing V2 polycarbonate, injection moulded.
Ecologic anti-aging injected sealing gasket.
Gear-tray reflector unit in hot-galvanized steel, painted in white polyester, fixed to the housing by means of steel rapid devices, hinged opening.
Diffuser in self-extinguishing V2 polycarbonate, photo-engraved interior, UV stabilised, injection moulded with smooth outer surface.
Snug fit safety snap-lock clips for diffuser mounting in stainless steel, screwdriver opening.
Fixing brackets in stainless steel.
Electrical characteristicsIn compliance with EN 60598-1.
Source characteristics
- Linear LED modules.
- Color initial tolerance (MacAdam): SDCM 3.
On request
- different colour rendering indices and colour temperatures
- wiring: dimmable, class II
- linear LED modules, with special protection against aggressive chemically-volatile substances, for standard LED technology
Applications
Dry, dusty indoor environments, subject to occasional water splashes.
Environments: transit areas, parking lots.
Environments where soft diffuse light is required for optimal visual comfort.
Virtually in all environments compatibly with the use of any chemicals which could compromise the use of plastic materials.
Not suitable in environments where chlorine fumes, ligroin, hydrocarbon mixtures, mineral oil vapours or fumes of lubricating emulsions to cool down machine tools are present.
Not suitable for installation on surfaces subject to important vibrations, exposed to weather conditions, on ropes or poles.
Luminaires suitable, from a hygienic point of view, for use in production plants in the food industry (HACCP / IFS / BRC-Standard).
Suitable for illumination of public car parks and parking grounds referred to DIN 67528:2018-04.
Pair of brackets and hooks in stainless steel, with nuts and bolts for fixing to 3F Linda, for ceiling or wall-mounting, single and twin-lamp luminaires.
Minimum tilt angle = 45°.
Code
Item
A0449
15 GZI (w/brack. Linda L300)
A0450
15 RIT (w/brack.+ hooks Linda L660-1270-1570)
Pair of brackets and hooks in stainless steel, with nuts and bolts for fixing to 3F Linda, for wall-mounting, single and twin-lamp luminaires.
Code
Item
A0451
15 MBI (w/brack. Linda L300)
A0452
15 FBR (w/brack.+ hooks Linda L660-1270-1570)
Pair of stainless steel hooks for suspended installation, with cable clip and nuts and bolts for installation to 3F Linda.
Code
Item
A0462
13 GSI (pair of susp. hooks Linda L300)
A0463
13 TRM (pair of susp. hooks Linda L660-1270-1570)
Wire-guard for applications in dry environments, against shocks coming from any directions, galvanized steel rod Ø 5 mm.
Code
Item
A0455
Wire guard 180x1330 03F/Linda
Installation instructionsDownload
IMI0191000.pdf A0456
Wire guard 180x1330 03F/Linda
Installation instructionsDownload
IMI0191000.pdf A0457
Wire guard280x1330 03F/Linda/Beta
Installation instructionsDownload
IMI0192000.pdf A0458
Wire guard 280x1630 03F/Linda/Beta
Installation instructionsDownload
IMI0192000.pdf Only for luminaires fixed without hooks.
Anti-condensation diffuser cable gland.
Code
Item
A0187
Anti-condensation cable gland
Recommended for installations in environments with temperature sudden changes or subject to condensation.
Pictograms for warning signs to be applied on emergency luminaire's diffusers 160 mm wide.
Pictogram, 135 mm high, 240 mm long for L300 luminaires, 605 mm long for L660 luminaires.
Pictograms complying with European standards concerning health and safety signals on the workplace.
Code
Item
A0464
26 CSG (pictogram P1 Linda L300)
A0465
26 MTH (pictogram P1 Linda L660)
Pictograms for warning signs to be applied on emergency luminaire's diffusers 160 mm wide.
Pictogram, 135 mm high, 240 mm long for L300 luminaires, 605 mm long for L660 luminaires.
Pictograms complying with European standards concerning health and safety signals on the workplace.
Code
Item
A0466
26 DVI (pictogram P2 Linda L300)
A0467
26 MVL (pictogram P2 Linda L660)
Pictograms for warning signs to be applied on emergency luminaire's diffusers 160 mm wide.
Pictogram, 135 mm high, 240 mm long for L300 luminaires, 605 mm long for L660 luminaires.
Pictograms complying with European standards concerning health and safety signals on the workplace.
Code
Item
A0468
26 GZM (pictogram P3 Linda L300)
A0469
26 PXN (pictogram P3 Linda L660)