3F Rover Ampio
Distribuzione ampia: la superficie illuminata ha forma rettangolare.
Cablaggio elettronico ON/OFF 230V‑50/60Hz
Codice
Articolo
W
lm
K
CRI
L x A x H
IP
3F Rover S 18000/840 WIDE
102
17534
4000
>80
575x395x65
65
3F Rover S 25000/840 WIDE
150
25163
4000
>80
575x395x65
65
3F Rover D 35000/840 WIDE
202
35067
4000
>80
575x795x65
65
3F Rover D 50000/840 WIDE
300
50326
4000
>80
575x795x65
65
3F Rover S 18000/865 WIDE
102
17060
6500
>80
575x395x65
65
3F Rover S 25000/865 WIDE
150
24483
6500
>80
575x395x65
65
3F Rover D 35000/865 WIDE
202
34120
6500
>80
575x795x65
65
3F Rover D 50000/865 WIDE
300
48967
6500
>80
575x795x65
65
Cablaggio elettronico DALI 230V‑50/60Hz
Codice
Articolo
W
lm
K
CRI
L x A x H
IP
3F Rover S 18000/840 D2D WIDE
102
17534
4000
>80
575x395x65
65
3F Rover S 25000/840 D2D WIDE
150
25163
4000
>80
575x395x65
65
3F Rover D 35000/840 D2D WIDE
202
35067
4000
>80
575x795x65
65
3F Rover D 50000/840 D2D WIDE
300
50326
4000
>80
575x795x65
65
3F Rover S 18000/865 D2D WIDE
102
17060
6500
>80
575x395x65
65
3F Rover S 25000/865 D2D WIDE
150
24483
6500
>80
575x395x65
65
3F Rover D 35000/865 D2D WIDE
202
34120
6500
>80
575x795x65
65
3F Rover D 50000/865 D2D WIDE
300
48967
6500
>80
575x795x65
65
3F Rover Medio
Distribuzione media: la superficie illuminata ha forma quadrata.
Cablaggio elettronico ON/OFF 230V‑50/60Hz
Codice
Articolo
W
lm
K
CRI
L x A x H
IP
3F Rover S 18000/840 MEDIUM
102
17515
4000
>80
575x395x65
65
3F Rover S 25000/840 MEDIUM
150
25136
4000
>80
575x395x65
65
3F Rover D 35000/840 MEDIUM
202
35029
4000
>80
575x795x65
65
3F Rover D 50000/840 MEDIUM
300
50272
4000
>80
575x795x65
65
3F Rover S 18000/865 MEDIUM
102
17041
6500
>80
575x395x65
65
3F Rover S 25000/865 MEDIUM
150
24457
6500
>80
575x395x65
65
3F Rover D 35000/865 MEDIUM
202
34083
6500
>80
575x795x65
65
3F Rover D 50000/865 MEDIUM
300
48914
6500
>80
575x795x65
65
Cablaggio elettronico DALI 230V‑50/60Hz
Codice
Articolo
W
lm
K
CRI
L x A x H
IP
3F Rover S 18000/840 D2D MEDIUM
102
17515
4000
>80
575x395x65
65
3F Rover S 25000/840 D2D MEDIUM
150
25136
4000
>80
575x395x65
65
3F Rover D 35000/840 D2D MEDIUM
202
35029
4000
>80
575x795x65
65
3F Rover D 50000/840 D2D MEDIUM
300
50272
4000
>80
575x795x65
65
3F Rover S 18000/865 D2D MEDIUM
102
17041
6500
>80
575x395x65
65
3F Rover S 25000/865 D2D MEDIUM
150
24457
6500
>80
575x395x65
65
3F Rover D 35000/865 D2D MEDIUM
202
34083
6500
>80
575x795x65
65
3F Rover D 50000/865 D2D MEDIUM
300
48914
6500
>80
575x795x65
65
3F Rover Concentrato
Distribuzione concentrata ellittica.
Cablaggio elettronico ON/OFF 230V‑50/60Hz
Codice
Articolo
W
lm
K
CRI
L x A x H
IP
3F Rover S 18000/840 CONC
102
17136
4000
>80
575x395x65
65
3F Rover S 25000/840 CONC
150
24592
4000
>80
575x395x65
65
3F Rover D 35000/840 CONC
202
34271
4000
>80
575x795x65
65
3F Rover D 50000/840 CONC
300
49185
4000
>80
575x795x65
65
3F Rover S 18000/865 CONC
102
16673
6500
>80
575x395x65
65
3F Rover S 25000/865 CONC
150
23928
6500
>80
575x395x65
65
3F Rover D 35000/865 CONC
202
33347
6500
>80
575x795x65
65
3F Rover D 50000/865 CONC
300
47856
6500
>80
575x795x65
65
Cablaggio elettronico DALI 230V‑50/60Hz
Codice
Articolo
W
lm
K
CRI
L x A x H
IP
3F Rover S 18000/840 D2D CONC
102
17136
4000
>80
575x395x65
65
3F Rover S 25000/840 D2D CONC
150
24592
4000
>80
575x395x65
65
3F Rover D 35000/840 D2D CONC
202
34271
4000
>80
575x795x65
65
3F Rover D 50000/840 D2D CONC
300
49185
4000
>80
575x795x65
65
3F Rover S 18000/865 D2D CONC
102
16673
6500
>80
575x395x65
65
3F Rover S 25000/865 D2D CONC
150
23928
6500
>80
575x395x65
65
3F Rover D 35000/865 D2D CONC
202
33347
6500
>80
575x795x65
65
3F Rover D 50000/865 D2D CONC
300
47856
6500
>80
575x795x65
65
3F Rover HRL
Distribuzione concentrata (Rack washer).
Cablaggio elettronico ON/OFF 230V‑50/60Hz
Codice
Articolo
W
lm
K
CRI
L x A x H
IP
3F Rover S 18000/840 HRL
104
17079
4000
>80
575x395x65
65
3F Rover S 25000/840 HRL
150
24511
4000
>80
575x395x65
65
3F Rover D 35000/840 HRL
202
34158
4000
>80
575x795x65
65
3F Rover D 50000/840 HRL
300
49022
4000
>80
575x795x65
65
3F Rover S 18000/865 HRL
104
16618
6500
>80
575x395x65
65
3F Rover S 25000/865 HRL
150
23849
6500
>80
575x395x65
65
3F Rover D 35000/865 HRL
202
33236
6500
>80
575x795x65
65
3F Rover D 50000/865 HRL
300
47698
6500
>80
575x795x65
65
Cablaggio elettronico DALI 230V‑50/60Hz
Codice
Articolo
W
lm
K
CRI
L x A x H
IP
3F Rover S 18000/840 D2D HRL
104
17079
4000
>80
575x395x65
65
3F Rover S 25000/840 D2D HRL
150
24511
4000
>80
575x395x65
65
3F Rover D 35000/840 D2D HRL
202
34158
4000
>80
575x795x65
65
3F Rover D 50000/840 D2D HRL
300
49022
4000
>80
575x795x65
65
3F Rover S 18000/865 D2D HRL
104
16618
6500
>80
575x395x65
65
3F Rover S 25000/865 D2D HRL
150
23849
6500
>80
575x395x65
65
3F Rover D 35000/865 D2D HRL
202
33236
6500
>80
575x795x65
65
3F Rover D 50000/865 D2D HRL
300
47698
6500
>80
575x795x65
65
ILLUMINOTECNICHE
Distribuzione ampia, media e concentrata.
Durata utile (L80/B10): 100000 h. (tq+25°C)
Sicurezza fotobiologica RG0.
SORGENTE
Moduli LED lineari.
Tolleranza iniziale del colore (MacAdam): SDCM 3.
MECCANICHE
Corpo in alluminio verniciato a polvere epossipoliestere di colore bianco dotato di una piastra con spessore elevato per una dissipazione termica più efficace.
Carter copricablaggio in policarbonato di colore bianco.
Guarnizione di tenuta poliuretanica espansa, ecologica, antinvecchiamento, posata tramite processo automatico continuo con assenza di giunzioni.
Staffa di fissaggio in acciaio inox.
Lenti 3F Lens in metacrilato (PMMA) trasparente con superficie esterna piana, ad alta efficienza luminosa.
ELETTRICHE
Conformità alla EN 60598‑1.
Unità elettrica ispezionabile.
La conformità dell'apparecchio alla norma EN 60598‑2‑22, per alimentazione da un sistema di emergenza centralizzato CPSS, è da verificare nelle schede tecniche dei singoli apparecchi, scaricabili dal nostro sito internet.
Connessione rapida tramite connettore 3/5 P.
INSTALLAZIONE
Installazione a sospensione o a plafone tramite accessorio.
APPLICAZIONI
Temperatura ambiente da ‑30°C fino a +50°C.
Ambienti interni asciutti, polverosi, con occasionali getti d'acqua.
Ambienti commerciali, espositivi e industriali, magazzini, aree aperte o con scaffali.
Ambienti in cui si ritiene necessaria una protezione totale contro la caduta di frammenti (ad esempio ambienti con prodotti alimentari o macchine con parti in movimento o con elevati sbalzi di temperatura), utilizzare apparecchi con lenti in policarbonato.
Prodotto adatto per impianti produttivi alimentari (HACCP), IFS (Food), BRC (GSFS Food).
I prodotti DALI sono conformi al CAM (DM 24/11/2025).
GESTIONE DELLA LUCE
I prodotti DALI possono essere controllati con la tecnologia 3F Easy Dim o 3F Wireless ZQ.
AVVERTENZE
Apparecchio non idoneo per celle frigorifere con temperatura ambiente <0°C e/o con umidità relativa >85%.
A RICHIESTA
- potenze, rese cromatiche o temperature di colore differenti
- versioni per applicazioni sportive (resistenza al lancio della palla)
- lenti in policarbonato (IK08)
- corpo in colore RAL differente
- doppia accensione per versioni ON/OFF
- cablaggio: CLO
- doppio ingresso linea di alimentazione / segnale
- versioni in emergenza
Codice
Articolo
Coppia staffe soffitto Rover
Staffe per l'installazione dell'apparecchio a soffitto, in acciaio inox.
Kit di 6 moschettoni per fissare l'apparecchio a catena tramite doppia sospensione a Y, in acciaio zincato.
Codice
Articolo
Riduttore pressacavo ø7-9mm per CR 3P
La confezione contiene 10 pezzi.Riduttore pressacavo ø13-17mm per CR 5P
La confezione contiene 10 pezzi.A01006 compatibile con versioni ON/OFF, SENSEHBZQ e SENSEMBZQ, consente la riduzione dell'ingresso linea standard da ø9‑13mm a ø7‑9mm.
A01007 compatibile con versioni EP e D2D, consente l'aumento dell'ingresso linea standard da ø9‑13mm a ø13‑17mm.