3F Rover Large
Distribution large de forme rectangulaire.
Câblage électronique ON/OFF 230V‑50/60Hz
Code
Article
W
lm
K
CRI
L x A x H
IP
3F Rover S 18000/840 WIDE
102
17450
4000
>80
575x395x65
65
3F Rover S 25000/840 WIDE
150
25044
4000
>80
575x395x65
65
3F Rover D 35000/840 WIDE
202
34900
4000
>80
575x795x65
65
3F Rover D 50000/840 WIDE
300
50086
4000
>80
575x795x65
65
3F Rover S 18000/865 WIDE
102
16979
6500
>80
575x395x65
65
3F Rover S 25000/865 WIDE
150
24367
6500
>80
575x395x65
65
3F Rover D 35000/865 WIDE
202
33957
6500
>80
575x795x65
65
3F Rover D 50000/865 WIDE
300
48734
6500
>80
575x795x65
65
Câblage électronique DALI 230V‑50/60Hz
Code
Article
W
lm
K
CRI
L x A x H
IP
3F Rover S 18000/840 D2D WIDE
102
17450
4000
>80
575x395x65
65
3F Rover S 25000/840 D2D WIDE
150
25044
4000
>80
575x395x65
65
3F Rover D 35000/840 D2D WIDE
202
34900
4000
>80
575x795x65
65
3F Rover D 50000/840 D2D WIDE
300
50086
4000
>80
575x795x65
65
3F Rover S 18000/865 D2D WIDE
102
16979
6500
>80
575x395x65
65
3F Rover S 25000/865 D2D WIDE
150
24367
6500
>80
575x395x65
65
3F Rover D 35000/865 D2D WIDE
202
33957
6500
>80
575x795x65
65
3F Rover D 50000/865 D2D WIDE
300
48734
6500
>80
575x795x65
65
3F Rover Moyen
Distribution moyenne de forme carrée.
Câblage électronique ON/OFF 230V‑50/60Hz
Code
Article
W
lm
K
CRI
L x A x H
IP
3F Rover S 18000/840 MEDIUM
102
17431
4000
>80
575x395x65
65
3F Rover S 25000/840 MEDIUM
150
25017
4000
>80
575x395x65
65
3F Rover D 35000/840 MEDIUM
202
34862
4000
>80
575x795x65
65
3F Rover D 50000/840 MEDIUM
300
50032
4000
>80
575x795x65
65
3F Rover S 18000/865 MEDIUM
102
16961
6500
>80
575x395x65
65
3F Rover S 25000/865 MEDIUM
150
24340
6500
>80
575x395x65
65
3F Rover D 35000/865 MEDIUM
202
33921
6500
>80
575x795x65
65
3F Rover D 50000/865 MEDIUM
300
48681
6500
>80
575x795x65
65
Câblage électronique DALI 230V‑50/60Hz
Code
Article
W
lm
K
CRI
L x A x H
IP
3F Rover S 18000/840 D2D MEDIUM
102
17431
4000
>80
575x395x65
65
3F Rover S 25000/840 D2D MEDIUM
150
25017
4000
>80
575x395x65
65
3F Rover D 35000/840 D2D MEDIUM
202
34862
4000
>80
575x795x65
65
3F Rover D 50000/840 D2D MEDIUM
300
50032
4000
>80
575x795x65
65
3F Rover S 18000/865 D2D MEDIUM
102
16961
6500
>80
575x395x65
65
3F Rover S 25000/865 D2D MEDIUM
150
24340
6500
>80
575x395x65
65
3F Rover D 35000/865 D2D MEDIUM
202
33921
6500
>80
575x795x65
65
3F Rover D 50000/865 D2D MEDIUM
300
48681
6500
>80
575x795x65
65
3F Rover Concentrique
Distribution concentrée elliptique.
Câblage électronique ON/OFF 230V‑50/60Hz
Code
Article
W
lm
K
CRI
L x A x H
IP
3F Rover S 18000/840 CONC
102
17054
4000
>80
575x395x65
65
3F Rover S 25000/840 CONC
150
24476
4000
>80
575x395x65
65
3F Rover D 35000/840 CONC
202
34109
4000
>80
575x795x65
65
3F Rover D 50000/840 CONC
300
48951
4000
>80
575x795x65
65
3F Rover S 18000/865 CONC
102
16594
6500
>80
575x395x65
65
3F Rover S 25000/865 CONC
150
23814
6500
>80
575x395x65
65
3F Rover D 35000/865 CONC
202
33187
6500
>80
575x795x65
65
3F Rover D 50000/865 CONC
300
47628
6500
>80
575x795x65
65
Câblage électronique DALI 230V‑50/60Hz
Code
Article
W
lm
K
CRI
L x A x H
IP
3F Rover S 18000/840 D2D CONC
102
17054
4000
>80
575x395x65
65
3F Rover S 25000/840 D2D CONC
150
24476
4000
>80
575x395x65
65
3F Rover D 35000/840 D2D CONC
202
34109
4000
>80
575x795x65
65
3F Rover D 50000/840 D2D CONC
300
48951
4000
>80
575x795x65
65
3F Rover S 18000/865 D2D CONC
102
16594
6500
>80
575x395x65
65
3F Rover S 25000/865 D2D CONC
150
23814
6500
>80
575x395x65
65
3F Rover D 35000/865 D2D CONC
202
33187
6500
>80
575x795x65
65
3F Rover D 50000/865 D2D CONC
300
47628
6500
>80
575x795x65
65
3F Rover HRL
Distribution concentrée (Rack washer).
Câblage électronique ON/OFF 230V‑50/60Hz
Code
Article
W
lm
K
CRI
L x A x H
IP
3F Rover S 18000/840 HRL
104
16997
4000
>80
575x395x65
65
3F Rover S 25000/840 HRL
150
24395
4000
>80
575x395x65
65
3F Rover D 35000/840 HRL
202
33995
4000
>80
575x795x65
65
3F Rover D 50000/840 HRL
300
48788
4000
>80
575x795x65
65
3F Rover S 18000/865 HRL
104
16539
6500
>80
575x395x65
65
3F Rover S 25000/865 HRL
150
23735
6500
>80
575x395x65
65
3F Rover D 35000/865 HRL
202
33077
6500
>80
575x795x65
65
3F Rover D 50000/865 HRL
300
47470
6500
>80
575x795x65
65
Câblage électronique DALI 230V‑50/60Hz
Code
Article
W
lm
K
CRI
L x A x H
IP
3F Rover S 18000/840 D2D HRL
104
16997
4000
>80
575x395x65
65
3F Rover S 25000/840 D2D HRL
150
24395
4000
>80
575x395x65
65
3F Rover D 35000/840 D2D HRL
202
33995
6500
>80
575x795x65
65
3F Rover D 50000/840 D2D HRL
300
48788
6500
>80
575x795x65
65
3F Rover S 18000/865 D2D HRL
104
16539
6500
>80
575x395x65
65
3F Rover S 25000/865 D2D HRL
150
23735
6500
>80
575x395x65
65
3F Rover D 35000/865 D2D HRL
202
33077
6500
>80
575x795x65
65
3F Rover D 50000/865 D2D HRL
300
47470
6500
>80
575x795x65
65
TECHNIQUES DE L'ÉCLAIRAGE
Distribution large, moyenne et concentrée.
Durée utile (L80/B10): 100000 h. (tq+25°C)
Sécurité photobiologique RG0.
SOURCE
Modules LED linéaires.
Tolérance initiale couleur (MacAdam): SDCM 3.
MÉCANIQUES
Corps en aluminium recouvert de poudre époxy‑polyester blanche avec plaque épaisse pour une meilleure dissipation de la chaleur.
Couvercle en polycarbonate blanc.
Joint d'étanchéité en polyuréthane expansé, écologiques, anti‑vieillissement, posés au moyen d'un processus automatique continu sans points de jonction.
Étrier de fixation en acier inox.
Lentilles 3F Lens en méthacrylate transparent (PMMA) avec surface plane externe, à haute efficacité lumineuse.
ÉLECTRIQUES
En conformité avec la norme EN 60598‑1.
Unité électrique inspectable.
La conformité à la norme EN 60598‑2‑22 pour l'alimentation électrique à partir d'un système d'urgence centralisé CPSS doit être vérifiée dans les fiches techniques de chaque appareil sur notre site Web.
Connexion rapide par un connecteur 3/5 P.
INSTALLATION
Installation au plafond ou en suspension avec accessoire.
APPLICATIONS
Température ambiante de ‑30°C à +50°C.
Locaux intérieurs secs, poussiéreux, avec des jets d'eau occasionnels.
Locaux commerciaux, exposition et industrielle, des entrepôts, des zones ouvertes ou des étagères.
Dans les environnements dans lesquels il voit un besoin pour une protection totale contre la chute des fragments (par exemple des environnements avec des denrées alimentaires ou des machines avec des pièces mobiles ou avec des variations extrêmes de température), utiliser les luminaires avec des lentilles en polycarbonate.
Produit adapté dans les usines de production alimentaire (HACCP), IFS (Food Version 6), BRC (GSFS Food Version 7).
GESTION DE LA LUMIÈRE
Les produits DALI peuvent être commandés avec la technologie 3F Easy Dim ou 3F Smart Dimming.
MISE EN GARDE
Appareil non adapté aux chambres froides dont la température ambiante est <0°C et/ou l'humidité relative >85%.
SUR DEMANDE
- puissances, indice de rendu des couleurs ou températures de couleur différents
- versions pour applications sportives (resistance au lancement de la balle)
- verres en polycarbonate (IK08)
- corps d'une couleur RAL différente
- double allumage pour les versions ON/OFF
- câblage: CLO
- ligne d'alimentation/signal à double entrée
- versions d'urgence
Code
Article
Paire de supports plafond Rover
Étriers pour l'installation du luminaire au plafond, en acier inox.
Kit de 6 Mousqueton pour la fixation de la chaîne lumineuse au moyen d'une double suspension en Y, en acier galvanisé.
Code
Article
Réducteur de presse-étoupe ø7-9mm pour CR 3P
L'emballage contient 10 pièces.Réducteur de presse-étoupe ø13-17mm pour CR 5P
L'emballage contient 10 pièces.A01006 compatible avec les versions ON/OFF, SENSEHBZQ e SENSEMBZQ, réduit l'entrée de la ligne de ø9‑13mm à ø7‑9mm.
A01007 compatible avec les versions EP e D2D, augmente l'entrée de la ligne de ø9‑13mm à ø13‑17mm.